Products and Solutions

Product Introduction

The FRP water cooling towers are used to remove heat from various sources such as machinery or heated process material through the cooling of a water stream to a lower temperature. Common applications include cooling the circulating water used in oil refineries, petrochemical and other chemical plants. 

The cooling tower can be round, square or in other shape. Top mounted with fan motor, there is a dynamic water distribution system with an option of aluminum or SS spinkler.  The main construction material for body is FRP, which is quite light based on strong structure. 

1

Free Consultation Purchasing Hotline:+86-533-2727685

Product Advantages

* Tower body is made of FRP, which is anti-aging, anti-corrosion, without fading and distortion
* Low noise blower and unqiue noise elimination technology is adopted.
* Simple operation and maintenance, all steel structure brackets are galvanized


  • p662
Working Principle

Cooling of the water is achieved through direct contact of water with air. The air vaporizes a part of this water and cooling effect is provided primarily by an exchange of latent heat of vaporization resulting from evaporation of water. During this phenomenon, which is widely known as evaporative cooling, heat is transferred from water to air. This heat is then rejected to the atmosphere, either through the use of fans or natural convection.

At induced draft cooling towers, the incoming cooling water is injected throughout the cooling tower with a spray distribution header. The spray is directed downards to baffles for maximizing the time of contact of water with air. Maximizing of heat exchange surface area is accomplished through the 'cooling water fill', made of PVC, wood, metal or other material. Air enters the interior of cooling tower through properly designed 'louvers'. Air is drawn through the baffled area by big fans and causes the cooling of water. In order to avoid the entrapment of water droplets in the leaving air stream, special device called 'drift eliminators' are used.


Technical Parameter

 MODEL RTA 8T 10T 15T 20T 25T 30T 40T 50T 60T 80T 100T 125T 150T 175T 200T 225T 250T 300T 350T 400T 500T 600T 700T 800T 1000T 1250T  
 
FLOW m³/h 6.23 7.81 11.70 15.62 19.51 23.40 31.21 39.24 46.8 62.64 78.12 97.56 117.00 136.80 156.24 175.50 195.12 234 273.24 312.12 390.60 468.00 547.20 626.40 781.20 976.50  
WIND VOLUME CMM 70 85 140 160 200 230 280 330 420 450 700 830 950 1150 1250 1500 1750 2000 2200 2400 2600 3750 4200 5000 5400 7600  
SOUND VOLUME Dba 45.5 47 48 50 52 54 56.5 57.5 57 59 60 60 60 60 60 54 55 56 57 59 60 65 66 73 74 76  
MOTOR KW 0.18 0.18 0.37 0.55 0.75 0.75 1.5 1.5 1.5 1.5 2.25 2.25 2.25 3.75 3.75 5.5 5.5 7.5 7.5 11 11 15 15 20 20 20  
NET WEIGHT KG 42 46 54 67 98 120 130 190 240 260 500 540 580 860 880 1050 1080 1760 1800 2840 2900 3950 4050 4700 4900 6560  
WORKING WEIGHT KG 180 190 290 300 500 530 550 975 1250 1280 1600 1640 1680 1960 1980 2770 2800 3930 3970 5740 5800 9350 9450 11900 12100 11880  
TOWER HEIGHT TH 1655 1765 1685 1905 2000 1950 2050 2140 2340 2440 2400 2660 2780 3390 3600 4170 4170 4325 4325 4555 4555 5320 5520 5670 5870 6190  
CASING CH 990 1100 1000 1220 1200 1220 1250 1300 1330 1430 1460 1550 1650 1800 1900 2060 2060 2185 2185 2255 2255 2440 2640 2690 2890 3130  
WIND ENTRANCE AH 170 170 170 170 245 245 245 245 325 325 325 325 325 365 560 560 560 560 560 690 690 1020 1020 1020 1020 1020  
WATER BASE WH 320 320 340 340 360 360 360 400 410 410 465 465 465 465 465 900 900 900 900 900 900 1020 1020 1020 1020 1020  
WATER INLET IH 40 50 50 50 80 80 80 80 100 100 125 125 150 150 150 200 200 200 200 200 250 250 250 300 300 300  
FAN DIAMETER ED 550 635 635 770 770 770 930 930 1180 1180 1450 1450 1450 1750 1750 2135 2135 2440 2440 2745 2745 3400 3400 3700 3700 3700  
BASE DIAMETER WD 950 950 1190 1190 1430 1670 1670 1900 2150 2150 2960 2960 2960 3350 3350 4200 4200 4730 4730 5600 5600 6600 6600 7600 7600 8600  
WATER OUTLET OH 40 50 50 50 80 80 80 80 100 100 125 125 150 150 200 200 200 200 200 200 250 250 250 300 300 300  
OVER FLOW/DRAIN OF/DR 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 40/40 40/40 40/40 40/40 40/40 40/40 50/50 80/80 100/100 100/100 100/100 100/100 100/100  
FLOW/SUPPLY FV/QS 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 20/20 20/20 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 32/32 32/32 50/50 50/50 80/80 80/80 80/80  
FOUNDATION HEIGHT FH 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 400 400 400 400 400 400 400  
FOUNDATION WIDTH FS 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 400 400 400 400 400 400 400  
WATER CABINET BASE FC                     800 800 800 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000  
CENTRAL DIAMETER FD 473 473 779 779 1000 1110 1110 1350 1540 1540 2440 2440 2900 2900 3360 4170 4170 4780 4780 5650 5650 6650 6650 7650 7650 8500  
SCREW SPE. BC M10 M10 M10 M10 M10 M10 M12 M12 M12 M12 M12 M12 M12 M14 M14 M14 M14 M14 M14 M16 M16 M16 M16 M16 M16 M16  
SCREW BD 410 410 670 670 710 790 790 970 1120 1120 1145 1145 1145 1100 1100 3060 3060 3530 3530 2245 2245 2470 2470 2870 2870 3250  

 

Online requirements submission / Feedback

If any inquiry or place order, please fill out the following form so that we could contact you as soon as possible;

Name       
Tel            
Email       
Company Name    

Content

Contact Information

J.H. Chemical & Pharma Equipment Co.,Ltd

Address: No.200, Huaguang Road, Zibo, Shandong, China.

Factory address: No.35, Songlin Road, Zibo, Shandong, China.

+86-533-2727685

+86-533-2875625

sales@jh-equipment.com